4 Specification

This section contains the technical specification of the LucidControl RTD Input USB Module

Parameter Condition Value
Inputs
No. of Input Channels 4
Inputs – Electrical Characteristics
Measurement Method RTD Two wire measurement
Resolution 0.1 °C
Measurement Error typ. ±0.5 °C
Constant Measurement Current 0.5 mA
RTD Type Pt1000 DIN IEC 751
Inputs – Timing Characteristic
Scan Interval TScan 50 ms ≤ TScan ≤ 10 s
Setup Time TSetup 5 ms ≤ TSetup ≤ 1 s
Module – Host Interface
USB 2.0 Full Speed CDC Profile
Power Supply USB Bus Powered with +5V
No additional Power Supply needed
Maximum Rated Current 40 mA
Module – Environment
Temperature Storage -20 °C … +70 °C
Operation 0 °C … +55 °C
Humidity <85 % RH, non-condensing
Module – Housing
Dimensions L x W x H 90 x 54 x 62 mm
Weight (in total) 120 g
Assembly Rail-Mount (EN 50022, TS35)
Protection Class (DIN 40050) IP20
Module – Indicators
Operation and Status Indicator
Communication Indicator
Software
Supported Operating Systems Windows® XP, Windows® Vista, Windows® 7
Ubuntu, Debian, Raspbian
Application Programming Interface (API) Console / Terminal Application
Java and Python

[hr/]

[one_third first]
Previous Chapter:
3 Module Operation

[/one_third]

[one_third]
LucidControl RTD Input USB Module Content
[/one_third]

[one_third]
Next Chapter:
5 Order Information
[/one_third]