4 Specification
This section contains the technical specification of the LucidControl USB Analog Output Module.
Parameter | Condition | Value | |
---|---|---|---|
Outputs | |||
No. of Output Channels | 4 | ||
Outputs – Electrical Characteristics | |||
Output Function | Digital to Analog Conversion | ||
Resolution | 12 bit | ||
Accuracy | typ. ±0.25 % of full scale range |
||
Max. Output Error | ± 5 LSB | ||
Max. Output Current per Channel | IChMax | 40 mA | |
Max. Output Current of Device | ITotalMax | 160 mA | |
Output – Timing Characteristic | |||
Value Update Interval | TUpdate | typ. 10 ms | |
Setup Time for stable Output | TStable | typ. 1ms | |
DAC Conversion Time | TConv | typ. 1ms | |
Module – Communication | |||
USB | 2.0 Full Speed CDC Profile | ||
Module – Electrical Characteristics | |||
Power Supply | USB Bus Powered with +5V No additional Power Supply needed |
||
Maximum Rated Current | 250 mA | ||
Module – Environment | |||
Temperature | Storage | -20 °C … +70 °C | |
Operation | 0 °C … +55 °C | ||
Humidity | <85 % RH, non-condensing | ||
Module – Housing | |||
Dimensions L x W x H | 90 x 54 x 62 mm | ||
Weight (in total) | 120 g | ||
Assembly | Rail-Mount (EN 50022, TS35) | ||
Protection Class (DIN 40050) | IP20 | ||
Module – Indicators | |||
Operation and Status Indicator | |||
Communication Indicator | |||
Software | |||
Supported Operating Systems | Windows® XP, Windows® Vista, Windows® 7 Ubuntu, Debian, Raspbian |
||
Application Programming Interface (API) | Console / Terminal Application Java and Python |