4 Specification

This section contains the technical specification of the LucidControl Analog Input USB Module

Parameter Condition Value
Inputs
No. of Input Channels 4
Inputs – Electrical Characteristics
Measurement Method Analog to Digital Conversion
Voltage Range AI4-05 0 ~ 5 V
AI4-10 0 ~ 10 V
AI4-24 0 ~ 24 V
Resolution 14 bit
Accuracy typ. ±0.25 %
of full scale range
Max. Measurement Error ±5 LSB
Input Resistance 100 kΩ
Inputs – Timing Characteristic
Scan Interval TScan 50 ms ≤ TScan ≤ 10 s
Module – Host Interface
USB 2.0 Full Speed CDC Profile
Power Supply USB Bus Powered with +5V
No additional Power Supply needed
Maximum Rated Current 40 mA
Module – Environment
Temperature Storage -20 °C … +70 °C
Operation 0 °C … +55 °C
Humidity <85 % RH, non-condensing
Module – Housing
Dimensions L x W x H 90 x 54 x 62 mm
Weight (in total) 120 g
Assembly Rail-Mount (EN 50022, TS35)
Protection Class (DIN 40050) IP20
Module – Indicators
Operation and Status Indicator
Communication Indicator
Software
Supported Operating Systems Windows® XP, Windows® Vista, Windows® 7
Ubuntu, Debian, Raspbian
Application Programming Interface (API) Console / Terminal Application
Java and Python